Category 3: Upstream Energy and Distribution Losses
Finalize classification on the Scope 1 fuel or Scope 2 energy activity. Use Category 3 → Create or Create Category 3 Candidates in bulk. Unclassified or review-pending sources may be skipped. Child activities link to the source and use its quantity. Use one child per source and subtype, choose method and factor, and refresh after source changes.
| Subtype | Basis |
|---|---|
| Upstream fuel | Source fuel × Well-to-Tank factor |
| Upstream electricity | Consumption × upstream factor, separate from generation |
| Transmission and distribution loss | Consumption, documented loss rate basis, and generation factor |
| Upstream heat, steam, or cooling | Purchased energy × compatible upstream factor |
| Heat distribution loss | Consumption-based network loss rate and factor |
| Purchased electricity sold to end users | Separate sold quantity × generation factor |
Consumption-based loss equals consumption × rate. Grid-input-based loss equals delivered consumption × rate ÷ (1 − rate). At 1,000 kWh and 10%, these yield 100 and about 111.11 kWh. Use a documented rate and its actual basis.
Keep primary fuel and generation in Scope 1 or 2. Category 3 adds applicable upstream or loss effects. A Well-to-Wheel factor can already include Well-to-Tank emissions.